| The specification of the material, without a previous notice for the improvement
to change. The metal fittings of the attachment is standard goods, ccording to the climate in a building area, use the strong commercial item etc. The article of a blue character is an option. It is attached by the model. |
| Item | Picture | How to use |
|---|---|---|
| Log lumber | ![]() |
Wall,timber, etc (main part) planed, lamineted angle and round D cut, hand cut 88,92mm~204,210mm etc... |
| Stairs
It becomes the size put together on the building and by design. |
![]() |
With Loft typy only. Look the Fixture |
| Celling board | ![]() |
Drive the nail from under to the rafter. |
| Wall board | ![]() |
Part where log material is not used for partition among. |
| Corner board | 15*40mm | Coner of floor and wall,celling and wall. | f
| Gable board | width of 145mm | Rafter cover |
| Frame | Board of width 120~150mm | Use for door and window cover. |
| Floor board for room | ![]() |
Thickness 28mm @The board is thick, it installs directly in the floor joist. |
| Floor board for terrace, balcony |
![]() |
Antisepsis has been processed. |
| Floor beam | ![]() |
To use 45*145mm*2~3 |
| Rafter board | ![]() |
Two-by-six 45*145mm |
| Board for insulate hold | No planer | Can use other part. |
| T typy scantling Scantling for opening side (right & left) |
![]() |
Fitting for opening space (window,door) prevented from curving, and twisting. |
| Peg | Scantling for hole. | Lumber for connection of wall. |
| Roof board | ![]() |
Under the roof shingle. |
| Pillar For the terrace and in room. |
Scantling 100~120mm | Kit in for terrace and porch. |
| Jack | ![]() |
Use for pole. For measure's steel of measure. Please read the manual how it uses. |
| Asphalt single | ![]() |
For dampproof, on the foundation. |
| Log seal felt tape |
Width 2~3cm length 10m roll. | Airtight is hold. Between above the log to the under log. |
| Long bolt, and nut For use wall top. |
![]() |
Log wall be binded and strength. It nut is stability of the log wall top, bolt is insert at the log hole,(corner) and screw a normally nut, below the log wall. |
| Hardware L type plate, the rafter is installed on the wall top. |
![]() ![]() |
For constriction. |
| Entrance and terrace door We can receive special order. |
![]() ![]() |
Pair glass,insulated, auto lock, one or two door.The sliding door is not recommended.
The space can be done in the rail. The draft and the insect invade. Look at Fixture |
| Windows One door, double doors, top turn, fix |
![]() ![]() |
Many various sizes for Japan, with in mosquite net. Detail is Fixture |
| In room door All natural wood, and door with the glass |
![]() |
All natural tree, high grade. Detail is Fixture |
| Bay window Spacial order. Center fix, right & left doors, open and close |
![]() |
Size and many various designs. |